3 iR�V�`� @s�ddlZyddlmZWn ek r8ddlmZYnXddlZddlmZddlm Z m Z m Z m Z dZ ejd�ZddlmZmZmZmZmZddlmZGd d �d �ZGd d �d �ZGd d�de�ZGdd�de�ZdS)�N)�RLock)�process_introspection_data)� DBusException�IntrospectionParserException�MissingErrorHandlerException�MissingReplyHandlerExceptionZrestructuredtextz dbus.proxies)�BUS_DAEMON_IFACE�BUS_DAEMON_NAME�BUS_DAEMON_PATH�INTROSPECTABLE_IFACE� LOCAL_PATH)�is_py2c@s(eZdZdZdd�Zdd�Zdd�ZdS) �_DeferredMethodzXA proxy method which will only get called once we have its introspection reply. cCs||_|j|_||_||_dS)N)� _proxy_method� _method_name�_append�_block)�self� proxy_method�append�block�r�/usr/lib64/python3.6/proxies.py�__init__6sz_DeferredMethod.__init__cOs@d|ks|jdd�r(|j|j||�dS|j�|j||�SdS)N� reply_handler� ignore_replyF)�getrrr)r�args�keywordsrrr�__call__=s  z_DeferredMethod.__call__cOs|j|j||�dS)N)rr)rrrrrr� call_asyncHsz_DeferredMethod.call_asyncN)�__name__� __module__� __qualname__�__doc__rrr rrrrr2s rc@s(eZdZdZdd�Zdd�Zdd�ZdS) � _ProxyMethodz�A proxy method. Typically a member of a ProxyObject. Calls to the method produce messages that travel over the Bus and are routed to a specific named Service. cCsX|tkrtdt��||_||_||_||_tj|�||_|dk rNtj |�||_ dS)Nz1Methods may not be called on the reserved path %s) r r�_proxy� _connection�_named_service� _object_path�_dbus_bindingsZvalidate_member_namerZvalidate_interface_name�_dbus_interface)r�proxyZ connection�bus_name� object_pathZ method_nameZifacerrrrSs  z_ProxyMethod.__init__c Os|jdd�}|jdd�}|jdd�}|jdd�}|dk s@|dk rl|dkrPt��n|dkr`t��n |rltd��|jd|j�}|dkr�|dkr�|j}n|d|j}|jjj|d�}|s�|dk r�|j j |j |j ||j||||f|�n |j j |j |j ||j||f|�SdS) Nr� error_handlerrF� signaturez6ignore_reply and reply_handler cannot be used together�dbus_interface�.)�poprr� TypeErrorr+rr&�_introspect_method_maprr'r r(r)Z call_blocking) rrrrr/rr0r1�keyrrrrgsD       z_ProxyMethod.__call__c Os�|jdd�}|jdd�}|jdd�}|jd|j�}|dkrd|rN|d|j}n|j}|jjj|d�}|jj|j|j ||j||||f|�dS)Nrr/r0r1r2) r3r+rr&r5rr'r r(r))rrrrr/r0r1r6rrrr �s$    z_ProxyMethod.call_asyncN)r!r"r#r$rrr rrrrr%Ls,r%c@s�eZdZdZeZeZdZdZ dZ d%dd �Z e d d �ddd �Z e d d �ddd�Ze dd �ddd�Zd&dd�Zdd�Zdd�Zdd�Zdd�Zdd�Zdd�Zdd �Zd'd!d"�Zd#d$�ZeZdS)(� ProxyObjectz�A proxy to the remote Object. A ProxyObject is provided by the Bus. ProxyObjects have member functions, and can be called like normal Python objects. r��NTFc Ks<|jdd�}|dk rB|dk r$td��|}ddlm}|dtdd�|jd d�} | dk r�|dk rftd ��| }ddlm}|d tdd�|r�td d j|j����|r�|j�||_|dk r�t j |�||_ |_ t j |�||_|s�|j|�|_ d|_g|_i|_t�|_| �s|jtk�r&|j|_n|j|_|j�|_dS)a�Initialize the proxy object. :Parameters: `conn` : `dbus.connection.Connection` The bus or connection on which to find this object. The keyword argument `bus` is a deprecated alias for this. `bus_name` : str A bus name for the application owning the object, to be used as the destination for method calls and the sender for signal matches. The keyword argument ``named_service`` is a deprecated alias for this. `object_path` : str The object path at which the application exports the object `introspect` : bool If true (default), attempt to introspect the remote object to find out supported methods and their signatures `follow_name_owner_changes` : bool If true (default is false) and the `bus_name` is a well-known name, follow ownership changes for that name �busNz%conn and bus cannot both be specifiedr)�warnz`Passing the bus parameter to ProxyObject by name is deprecated: please use positional parametersr9)� stacklevel� named_servicez3bus_name and named_service cannot both be specifiedzjPassing the named_service parameter to ProxyObject by name is deprecated: please use positional parametersz>ProxyObject.__init__ does not take these keyword arguments: %sz, )r3r4�warningsr;�DeprecationWarning�join�keysZ_require_main_loop�_busr*Zvalidate_bus_namer(�_requested_bus_nameZvalidate_object_path�__dbus_object_path__Zactivate_name_owner�_pending_introspect�_pending_introspect_queuer5r�_introspect_lockr � INTROSPECT_STATE_DONT_INTROSPECT�_introspect_state�'INTROSPECT_STATE_INTROSPECT_IN_PROGRESS� _Introspect) rZconnr-r.Z introspectZfollow_name_owner_changes�kwargsr:r;r=rrrr�sJ           zProxyObject.__init__cCs|jS)N)r()rrrr� szProxyObject.a�The bus name to which this proxy is bound. (Read-only, may change.) If the proxy was instantiated using a unique name, this property is that unique name. If the proxy was instantiated with a well-known name and with ``follow_name_owner_changes`` set false (the default), this property is the unique name of the connection that owned that well-known name when the proxy was instantiated, which might not actually own the requested well-known name any more. If the proxy was instantiated with a well-known name and with ``follow_name_owner_changes`` set true, this property is that well-known name. cCs|jS)N)rC)rrrrrMsz[The bus name which was requested when this proxy was instantiated. cCs|jS)N)rD)rrrrrM$szThe object-path of this proxy.cKs"|jj|f|||j|jd�|��S)ax Arrange for the given function to be called when the given signal is received. :Parameters: `signal_name` : str The name of the signal `handler_function` : callable A function to be called when the signal is emitted by the remote object. Its positional arguments will be the arguments of the signal; optionally, it may be given keyword arguments as described below. `dbus_interface` : str Optional interface with which to qualify the signal name. If None (the default) the handler will be called whenever a signal of the given member name is received, whatever its interface. :Keywords: `utf8_strings` : bool If True, the handler function will receive any string arguments as dbus.UTF8String objects (a subclass of str guaranteed to be UTF-8). If False (default) it will receive any string arguments as dbus.String objects (a subclass of unicode). `byte_arrays` : bool If True, the handler function will receive any byte-array arguments as dbus.ByteArray objects (a subclass of str). If False (default) it will receive any byte-array arguments as a dbus.Array of dbus.Byte (subclasses of: a list of ints). `sender_keyword` : str If not None (the default), the handler function will receive the unique name of the sending endpoint as a keyword argument with this name `destination_keyword` : str If not None (the default), the handler function will receive the bus name of the destination (or None if the signal is a broadcast, as is usual) as a keyword argument with this name. `interface_keyword` : str If not None (the default), the handler function will receive the signal interface as a keyword argument with this name. `member_keyword` : str If not None (the default), the handler function will receive the signal name as a keyword argument with this name. `path_keyword` : str If not None (the default), the handler function will receive the object-path of the sending object as a keyword argument with this name `message_keyword` : str If not None (the default), the handler function will receive the `dbus.lowlevel.SignalMessage` as a keyword argument with this name. `arg...` : unicode or UTF-8 str If there are additional keyword parameters of the form ``arg``\ *n*, match only signals where the *n*\ th argument is the value given for that keyword parameter. As of this time only string arguments can be matched (in particular, object paths and signatures can't). )� signal_namer1r-�path)rBZadd_signal_receiverr(rD)rrN�handler_functionr1rrrr�connect_to_signal0s < zProxyObject.connect_to_signalc Cs>i}trd|d<|jj|j|jtddf|j|jfddi|��S)NTZ utf8_stringsZ Introspect�Zrequire_main_loopF)r rBr r(rDr �_introspect_reply_handler�_introspect_error_handler)rrLrrrrKss zProxyObject._IntrospectcCs*x|jD]\}}}|||�qWg|_dS)N)rF)rrrrrrr�_introspect_execute_queue~sz%ProxyObject._introspect_execute_queuecCsp|jj�zTyt|�|_Wn*tk rD}z|j|�dSd}~XnX|j|_d|_|j �Wd|jj �XdS)N) rG�acquirerr5rrT� INTROSPECT_STATE_INTROSPECT_DONErIrErU�release)r�data�errrrS�s   z%ProxyObject._introspect_reply_handlerc Cshtj�tjd|j|j|jj|jj|�|j j �z$tj d�|j |_ d|_|j�Wd|j j�XdS)Nz$Introspect error on %s:%s: %s.%s: %sz'Executing introspect queue due to error)�loggingZ basicConfig�_logger�errorr(rD� __class__r"r!rGrV�debugrHrIrErUrX)rr]rrrrT�s    z%ProxyObject._introspect_error_handlerc Cs4|jj�z|jdk r |jj�Wd|jj�XdS)N)rGrVrErrX)rrrr�_introspect_block�s   zProxyObject._introspect_blockc CsJ|jj�z.|j|jkr,|jj|||f�n |||�Wd|jj�XdS)N)rGrVrIrJrFrrX)r�callbackrrLrrr�_introspect_add_to_queue�s   z$ProxyObject._introspect_add_to_queuecCs,|jd�r|jd�rt|��n |j|�SdS)N�__)� startswith�endswith�AttributeError�get_dbus_method)r�memberrrr� __getattr__�s zProxyObject.__getattr__cCs<|j||j|j|j||�}|j|jkr8|j||j|j�}|S)a,Return a proxy method representing the given D-Bus method. The returned proxy method can be called in the usual way. For instance, :: proxy.get_dbus_method("Foo", dbus_interface='com.example.Bar')(123) is equivalent to:: proxy.Foo(123, dbus_interface='com.example.Bar') or even:: getattr(proxy, "Foo")(123, dbus_interface='com.example.Bar') However, using `get_dbus_method` is the only way to call D-Bus methods with certain awkward names - if the author of a service implements a method called ``connect_to_signal`` or even ``__getattr__``, you'll need to use `get_dbus_method` to call them. For services which follow the D-Bus convention of CamelCaseMethodNames this won't be a problem. ) �ProxyMethodClassrBr(rDrIrJ�DeferredMethodClassrbr`)rrhr1�retrrrrg�s   zProxyObject.get_dbus_methodcCsd|j|j|jt|�fS)Nz&)rBr(rD�id)rrrr�__repr__�szProxyObject.__repr__)NNNTF)N)N)r!r"r#r$r%rjrrkrHrJrWr�propertyr-�requested_bus_namer.rQrKrUrSrTr`rbrirgrn�__str__rrrrr7�s6 R  C    &r7c@s�eZdZdZdd�Zedd�ddd�ZeZedd�ddd �Zed d�ddd �Z ed d�ddd �Z edd�ddd�Z ddd�Z dd�Z ddd�Zdd�ZeZdS)� Interfacez�An interface into a remote object. An Interface can be used to wrap ProxyObjects so that calls can be routed to their correct D-Bus interface. cCs$t|t�r|j|_n||_||_dS)a:Construct a proxy for the given interface on the given object. :Parameters: `object` : `dbus.proxies.ProxyObject` or `dbus.Interface` The remote object or another of its interfaces `dbus_interface` : str An interface the `object` implements N)� isinstancerr� proxy_object�_objr+)r�objectr1rrrr�s  zInterface.__init__cCs|jjS)N)rur.)rrrrrMszInterface.Nz.The D-Bus object path of the underlying objectcCs|jjS)N)rur-)rrrrrMsz:The bus name to which the underlying proxy object is boundcCs|jjS)N)rurp)rrrrrM szGThe bus name which was requested when the underlying object was createdcCs|jS)N)ru)rrrrrM szThe underlying proxy objectcCs|jS)N)r+)rrrrrMszThe D-Bus interface representedcKs|s |j}|jj|||f|�S)aaArrange for a function to be called when the given signal is emitted. The parameters and keyword arguments are the same as for `dbus.proxies.ProxyObject.connect_to_signal`, except that if `dbus_interface` is None (the default), the D-Bus interface that was passed to the `Interface` constructor is used. )r+rurQ)rrNrPr1rrrrrQs  zInterface.connect_to_signalcCs2|jd�r|jd�rt|��n|jj||j�SdS)Nrc)rdrerfrurgr+)rrhrrrri"s zInterface.__getattr__cCs|dkr|j}|jj||�S)a&Return a proxy method representing the given D-Bus method. This is the same as `dbus.proxies.ProxyObject.get_dbus_method` except that if `dbus_interface` is None (the default), the D-Bus interface that was passed to the `Interface` constructor is used. N)r+rurg)rrhr1rrrrg(szInterface.get_dbus_methodcCsd|j|jt|�fS)Nz%)rur+rm)rrrrrn4szInterface.__repr__)N)N)r!r"r#r$rror.rDr-rprtr1rQrirgrnrqrrrrrr�s&      rr)r[Z threadingr� ImportErrorZdummy_threadingr*Zdbus._expat_introspect_parserrZdbus.exceptionsrrrrZ __docformat__Z getLoggerr\rr r r r Z dbus._compatr rr%rvr7rrrrrr�s"   `B